Triplelite
Firefloor™ Fire resistant glass floor
system
Product width(s): 34mm
Maximum panel size: 1.1m x 3.0m
Maximum weight: 2200kg
A revolution
in insulated glass fire flooring
Non-fire rated materials will last only a
short time before softening and collapsing,
allowing fire to spread quickly from level
to level, endangering life and destroying
property. Triple Lite™ Firefloor incorporating
Pilkington Pyrostop™ will protect for
over one hour for both integrity and insulation,
allowing safe evacuation of people and prolonged
protection to the building fabric.
Triple-Lite™ Firefloor is a single layer
glass to glass butt jointed system, suitable
for domestic and commercial glass floor applications.
The key breakthrough with Triple-Lite™
Firefloor is its tested ability to withstand
over 60 minutes of fire challenge. The complete
glass, frame and supporting system with all
components has been fully tested to the new
UK and European fire floor standards, meaning
that Triple-lite™ Firefloor is the only
glass floor that can be specified for both
fire exit routes and pedestrian traffic.
Triple-Lite™ Firefloor, incorporating
Pilkington Pyrostop™, is designed, manufactured
and installed across the UK and Europe by
Glazeguard (S.W.) Ltd.
Installation
data
In order to meet the stringent requirements
for a Firefloor installation can only be carried
out by Glazeguard (S.W.) Ltd or one of their
approved installers. Design dimensions are
available on request.
GGGA10: Triple-Lite Firefloor
image to be added
GGGA11: Triple-Lite Firefloor
image to be added
Features
Large
panel sizes - up to 3m x 1.1m panels
can be abutted to form larger glass
floors.
Fully
load and fire tested - meets all current
requirements for European and UK standards
as well as UK building regulations.
Integrity
after fire - Triplelite™ Firefloor
remains useable even after 60 minutes
of fire testing.
Natural
light - all the benefits of a glass
floor for natural light transmission
with the additional benefit of a 60
minute fire rating. This allows glass
to be used where not previously possible.
Applications
Technical Data
Triple-Lite™ Firefloor is tested to
current UK standards and approved by CE mark
to all current relevant European standards
(EN 1365 part 2:2000, EN 12543 pts 1-6, EN
14449 & calculated in accordance with
BS 6399). Tested to loads of 4.5Kn uniform
and 5.0Kn/m2 concentrated in accordance with
BS 6399. Test at the Building Research Establishment
(BRE) in the UK, the test included simultaneous
loaded and fired test. The Triple-Lite™
Firefloor sustained full commercial loading
and retained its integrity in excess of 60
minutes, passing all required safety standards.
On completion of the fire test Triple-Lite™
Firefloor remained undamaged and able to sustain
full commercial loading.
Triple-Lite™
Firefloor under test at
Building Research Establishment (B.R.E.
UK)
Span
Loadings
Application
Integrity
(minutes)
Insulation
(minutes)
Domestic
60
60
Office
60
60
Commercial
60
60
Integrity:
Floor retains its structural
form without failure.
Insulation: The temperature
of the top surface of the
floor does not exceed the
temperature guidelines in
EN 1363/1365.
Application
Load
- Concentrated
(kN)
Load
- Uniform
(kN/m2)
Domestic
1.4
1.5
Office
3.6
2.0
Commercial
4.5
5.0
Above
loadings should be specific
to the application and approved
by the project Structural
Engineer
The relevant loads applied
will determine the construction
and the unsupported span
of each Triple-Lite™
Firefloor panel